If your application is to control the conditions (moisture or temperature and moisture) of a given space, room or building, whether with a stand alone system or in conjunction with an existing system, use this Survey Sheet to identify the requirements and design factors of your application.

 You can complete and submit this survey sheet online. Additionally, you can download the survey sheet here; print, complete and fax this sheet to us at: 740-965-5470.

Customer
Contact
Email
Phone
Fax
Job Name & Location
Application
Date Quote Required
Date Equipment Required
Instructions
Application Information  
What is the type of dehumification required? Process Air Only
Condition Space
Provide air to existing AHU

Will Bry-Air provide cooling or temperature control?

Yes
No
If yes, indicate here Makeup Air/Inlet
Supply
Space
What is the cooling method to be used? DX
CHW
If DX, is Bry-Air to supply the condensing unit? Yes
No
What is the precision of design conditions required? RH

Temp 
Conditions
°FDB
°FWB
GR/LB
%RH
Outdoor Ambient
Surrounding Space
Controlled Space Design
   
Room Size L  x W  x H

CUBIC FEET
   
Construction  
Walls Material

Thickness

Type V.P.
Walls Material

Thickness

Type V.P.
Ceiling Material

Thickness

Type V.P.
Floor Material

Thickness

Type V.P.
   
Doors
Type
Width
Height
Openings/HR
Qty
Qty
Qty
   
Fixed Openings
(Conveyors, Windows, etc.)
Type
Width
Height
Usage
Qty
Qty
   
People Number
Type of Work Light
Moderate
Heavy
Other products or moisture loads  
LBS/HR
LBS/HR
GR/HR
GR/HR
Open Water  
Square Feet
Temperature °F
Velocity of Air FPM
   
Dehumidifier Options Required Weatherproofing
UL Listed
Process Fan
Cassette Only
Heating Type

Amount
Humidification Type

Amount
Piping & Controls Cooling
Steam Reactivation
Heating
Humdification
   
Make-up air (Outside air)  
CFM
°FDB
°FWB
Induction Through DEH
AHU
   
Exhaust Air  
CFM
Contaminates
   
Filters Required  
Process Inlet

Cleanable
Disposable
Make-up Air

Cleanable
Disposable
Process Outlet

Cleanable
Disposable
React Inlet

Cleanable
Disposable
   
Static Pressures Required
Inlet
Outlet
External
Process
1.5 "
Other
React
0.75"
Other
   
Internal Sensible Loads
(If total known, enter directly in first line)
 
Total BTUH
Lights Watts
Motor Driven In

Driven Out

HP
Materials

Specific Heat

LBS/HR
Other
   
Insulation
Type
Thickness
U Factor
(1/R factor)
Walls
Ceiling
Floor
   
Services Available  
Electric Volts

Phase

Hz
Steam PSIG
Hot Water

GPM

PSIG
Gas Natural
Propane
BTU/CU.FT.
Water

GPM

% Glycol

PSIG
Refrigeration Type @ BTUH